Follow us :

DINGFENG CAPACITOR - Please explain for the formula for Temperature Rise within a Capacitor.

Q: DINGFENG CAPACITOR - Please explain for the formula for Temperature Rise within a Capacitor.

 

A: Put simply. The temperature rise formula is the rms AC current( ripple) squared times the ESR of the capacitor at the operating frequency divided by a thermal constant multiplied by the surface area of the capacitor.

 

IF the calculated temperature rise is greater than 10C then the capacitor is being overstressed and will eventualy fail sooner than it should.

 

E-mail/Skype: info@dfcapacitor.com

Tel/WhatsApp: +86 15057271708

Wechat: 13857647932

Skype: Mojinxin124